Step 1
Maintain control of the patient, while placing a cervical collar.
Step 2
One rescuer approaches the patient from behind with the O.R.V.-Plus, and wraps it around the patient.
Step 3
The rescuer in front pulls the flaps under the patient’s arms and around to the front (Figure 29).
Step 4
The middle (yellow buckle) strap is fastened and tightened. The other straps may be used, if the patient warrants additional securing (Figure 30).
Step 5
Place a long spine board against the O.R.V.-Plus and patient.
Step 6
Place one strap (orange with black buckles) through each of the two side handles on the O.R.V.-Plus (Figure 31).
Step 7
Pass each of the straps through a high hand hold on the long board (Figure 31). |
Step 8
Snap the male and female buckles together (Figure 31).
Step 9
Tighten the straps until the O.R.V.-Plus is carrying the weight of the patient (Figure 32).
Step 10
One rescuer stands on each side of the long board (Figure 33).
Step 11
Place one hand through the hand hold at the patients armpit area.
Step 12
Place one hand just below the patients buttocks area (Figure 33).
Step 13
In one controlled motion, each rescuer takes one step in the head direction as the board is lowered and leveled. Note: Be mindful of your back as the board tilts the patient’s full weight will be in your hands (Figure 34).
Step 14
Place the patient on the ground for additional strapping, or place them directly on your cot for securing. |